Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Clin Transplant ; 37(4): e14904, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36594638

RESUMEN

BACKGROUND: The new United Network for Organ Sharing (UNOS) heart allocation policy prioritizes temporary percutaneous over durable left ventricular assist devices (LVAD) as bridge to transplant. We sought to examine 1-year outcomes of heart transplant recipients bridged with Impella versus durable LVADs. METHODS: All primary adult orthotopic heart transplant recipients registered in UNOS between January 2016 and June 2021 were analyzed. Recipients were identified as being bridged with isolated durable or percutaneous LVAD at the time of transplant. Baseline characteristics were compared and 1-year survival was examined using the Kaplan Meier method and multivariable Cox proportional hazards regression. RESULTS: During our study period, heart transplant recipients bridged with LVADs were divided between 5422(94%) durable and 324(6%) percutaneous options. Impella-bridged recipients were more likely to be status 1A under the old allocation system (98% vs. 70%, p < .01) and status 2 or higher under the new allocation system (99% vs. 24%, p < .01). Impella-bridged recipients were less likely to be obese (27% vs. 42%, p < .01), have ischemic cardiomyopathy (27% vs. 34%, p < .01), and were more likely to be on inotropic agents at the time of transplant (68% vs. 6%, p < .01). One-year post-transplant survival was not significantly different between the two groups on univariable (HR .87, 95% CI .56-1.37) or multivariable analysis (aHR .63, 95% CI .37-1.07). CONCLUSIONS: Following the UNOS allocation policy change, Impella utilization has increased with no significant difference in 1-year survival compared to bridge with durable LVADs. Impella may be a reasonable alternative to durable LVADs in select patients.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Adulto , Humanos , Resultado del Tratamiento , Supervivencia de Injerto , Insuficiencia Cardíaca/cirugía , Estudios Retrospectivos
3.
Tex Heart Inst J ; 50(1)2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36695735

RESUMEN

BACKGROUND: Aortic valve replacement improves survival for patients with low-gradient aortic valve stenosis, but there is a paucity of data on postoperative quality of life for this population. METHODS: In a single-center retrospective analysis of 304 patients with severe aortic valve stenosis who underwent transcatheter aortic valve replacement, patients were divided into 4 groups based on mean pressure gradient, left ventricular ejection fraction, and stroke volume index. Using the Kansas City Cardiomyopathy Questionnaire-12, quality of life was assessed immediately before and 1 month after transcatheter aortic valve replacement. RESULTS: Most patients in the low-flow, low-gradient group were men; this group had higher relative rates of cardiovascular disease and type 2 diabetes than the paradoxical low-flow, low-gradient group; the normal-flow, low-gradient group; and the high-gradient group. All-cause mortality did not differ significantly among the groups at 1 month after surgery, and all groups experienced a significant improvement in quality-of-life scores after surgery. The mean improvement was 27 points in the low-flow, low-gradient group, 25 points in the paradoxical low-flow, low-gradient group, 30 points in the normal-flow, low-gradient group, and 30 points in the high-gradient group (all P < .001). CONCLUSION: Quality of life improves significantly across all subgroups of aortic valve stenosis after trans-catheter aortic valve replacement, regardless of flow characteristics or aortic valve gradients.


Asunto(s)
Estenosis de la Válvula Aórtica , Diabetes Mellitus Tipo 2 , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Volumen Sistólico , Función Ventricular Izquierda , Calidad de Vida , Estudios Retrospectivos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad
5.
Am Heart J ; 254: 23-29, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35970399

RESUMEN

STUDY OBJECTIVE: To evaluate the impact of the new donor heart allocation system implemented in the United States in October 2018 on development of early cardiac allograft vasculopathy (CAV). DESIGN: Retrospective cohort study. PARTICIPANTS: Adult (≥ 18 years) heart transplant recipients registered in the United Network for Organ Sharing database between October 18, 2015 and October 17, 2018 (old system) and October 18, 2018 and May 31, 2020 (new system). MAIN OUTCOME MEASURE: Incidence of angiographic CAV at 1 year (accelerated CAV) in the overall transplant population and among the highest acuity subgroup-Status 1A (old) and Status 1 or 2 (new). We included recipient and donor demographic, cardiovascular, and transplant factors in multivariable logistic regression models to identify predictors of accelerated CAV. RESULTS: Of 10,375 transplant recipients, 6,660 (64%) and 3,715 (36%) were listed in the old and new allocation cohorts, respectively. The incidence of accelerated CAV was 521 (8%) in the old period compared with 272 (7%) in the new period (P = .36). Similar incidence rates were observed in the highest acuity subgroup-363 (8%) compared with 143 (7%), respectively (P = .13). In adjusted analyses of the high-acuity cohort, the new allocation system was not associated with a higher likelihood of accelerated CAV (odds ratio = 0.87, 95% confidence interval: 0.70-1.08, P = .20). CONCLUSIONS: The new donor heart allocation system is not associated with development of accelerated angiographic CAV at 1 year, including among recipients requiring the most urgent transplants.


Asunto(s)
Trasplante de Corazón , Donantes de Tejidos , Adulto , Humanos , Estados Unidos/epidemiología , Estudios Retrospectivos , Receptores de Trasplantes , Incidencia
6.
J Thorac Cardiovasc Surg ; 163(6): 2155-2162.e4, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-33676757

RESUMEN

OBJECTIVE: The importance of nontechnical skills in surgery is widely recognized. We demonstrate the feasibility of administering and assessing the results of a formal Non-Technical Skills in Surgery (NOTSS) curriculum to cardiothoracic surgery residents. METHODS: Eight cardiothoracic surgery residents participated in the NOTSS curriculum. They were assessed on their cognitive (situation awareness, decision-making) and social (communication and teamwork, leadership) skills based on simulated vignettes. The residents underwent pretraining NOTSS assessments followed by self-administered confidence ratings regarding the 4 skills. Subsequently, a formal NOTSS lecture was delivered and additional readings from the NOTSS textbook was assigned. A month later, the residents returned for post-training NOTSS assessments and self-administered confidence ratings. Changes across days (or within-day before vs after curriculum) were assessed using Wilcoxon signed rank test. RESULTS: There was a significant improvement in the overall NOTSS assessment score (P = .01) as well as in the individual categories (situation awareness, P = .02; decision-making, P = .02; communication and teamwork, P = .01; leadership, P = .02). There was also an increase in resident self-perception of improvement on the post-training day (P = .01). CONCLUSIONS: We have developed a simulation-based NOTSS curriculum in cardiothoracic surgery that can be formally integrated into the current residency education. This pilot study indicates the feasibility of reproducible assessments by course educators and self-assessments by participating residents in nontechnical skills competencies.


Asunto(s)
Cirugía General , Internado y Residencia , Entrenamiento Simulado , Competencia Clínica , Curriculum , Educación de Postgrado en Medicina , Cirugía General/educación , Humanos , Proyectos Piloto , Entrenamiento Simulado/métodos
7.
Am J Cardiol ; 166: 122-126, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-34949471

RESUMEN

Fractional flow reserve (FFR) determines the functional significance of epicardial stenoses assuming negligible venous pressure (Pv) and microvascular resistance. However, these assumptions may be invalid in end-stage liver disease (ESLD) because of fluctuating Pv and vasodilation. Accordingly, all patients with ESLD who underwent right-sided cardiac catheterization and coronary angiography with FFR as part of their orthotopic liver transplantation evaluation between 2013 and 2018 were included in the present study. Resting mean distal coronary pressure (Pd)/mean aortic pressure (Pa), FFR, and Pv were measured. FFR accounting for Pv (FFR - Pv) was defined as (Pd - Pv)/(Pa - Pv). The hyperemic effect of adenosine was defined as resting Pd/Pa - FFR. The primary outcome was all-cause mortality at 1 year. In 42 patients with ESLD, 49 stenoses were interrogated by FFR (90% were <70% diameter stenosis). Overall, the median model for ESLD score was 16.5 (10.8 to 25.5), FFR was 0.87 (0.81 to 0.94), Pv was 8 mm Hg (4 to 14), FFR-Pv was 0.86 (0.80 to 0.94), and hyperemic effect of adenosine was 0.06 (0.02 to 0.08). FFR-Pv led to the reclassification of 1 stenosis as functionally significant. There was no significant correlation between the median model for ESLD score and the hyperemic effect of adenosine (R = 0.10). At 1 year, 13 patients had died (92% noncardiac in etiology), and patients with FFR ≤0.80 had significantly higher all-cause mortality (73% vs 17%, p = 0.001. In conclusion, in patients with ESLD who underwent orthotopic liver transplantation evaluation, Pv has minimal impact on FFR, and the hyperemic effect of adenosine is preserved. Furthermore, even in patients with the predominantly angiographically-intermediate disease, FFR ≤0.80 was an independent predictor of all-cause mortality.


Asunto(s)
Estenosis Coronaria , Enfermedad Hepática en Estado Terminal , Reserva del Flujo Fraccional Miocárdico , Hiperemia , Adenosina , Cateterismo Cardíaco , Constricción Patológica , Angiografía Coronaria , Estenosis Coronaria/diagnóstico , Estenosis Coronaria/cirugía , Vasos Coronarios , Enfermedad Hepática en Estado Terminal/cirugía , Humanos , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad
8.
J Card Surg ; 36(8): 2722-2728, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34047391

RESUMEN

OBJECTIVE: Unrecognized left ventricular thrombi (LVT) can have devastating clinical implications and precludes patients with end-stage heart failure from undergoing left ventricular assist device (LVAD) implantation without cardiopulmonary bypass assistance. We assessed the reliability of an echocardiogram to diagnose LVT in patients with end-stage heart disease who underwent LVAD implantation. METHODS: A single-center retrospective study evaluated 232 consecutive adult patients requiring implantation of durable LVADs between 2005 and 2019. The validity of preoperative transthoracic echocardiogram (TTE) and intraoperative transesophageal echocardiogram (TEE) for diagnosing LVT was compared to direct inspection at the time of LVAD implantation. RESULTS: There were 232 patients that underwent LVAD implantation, with 226 patients (97%) receiving a preoperative TTE. Of those 226 patients, 32 patients (14%) received ultrasound enhancing agents (UEA). Intraoperative TEE images were available in 195 patients (84%). The sensitivity of TTE without UEA was 22% and specificity was 90% for detecting LVT, compared to 50% and 86%, respectively, for TTE with UEA. For intraoperative TEE, the sensitivity and specificity were 46% and 96%, respectively. The false omission rate ranged from 4% to 8% for all modalities of echocardiography. CONCLUSION: Among patients undergoing LVAD implantation, preoperative TTE and intraoperative TEE had poor sensitivity for LVT detection. Up to 8% of echocardiograms were incorrectly concluded to be negative for LVT on surgical validation. The low sensitivity and positive predictive value for diagnosing LVT suggest that echocardiography has limited reliability in this cohort of patients who are at high risk of LVT formation and its subsequent complications.


Asunto(s)
Corazón Auxiliar , Trombosis , Adulto , Ecocardiografía , Humanos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Trombosis/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...